Welcome to Our Company

Tap Changers

Our tap changers are components in transformers that consider variable hand proportions to be chosen over discrete strides. Transformers with our components acquire this variable turn proportion through interfacing with various access points acknowledged as taps with either the secondary or primary winding. Offered systems normally possess 33 taps and permit for 10% variety from the ostensible transformer rating that, thus, permits for stepped current direction of output. Our tap changer machines persist in two essential sorts, no load tap changers that must be de-stimulated prior to the turn proportion is balanced and on load tap changers that may alter their turn proportion amid operation. The tap choice on any of our tap changer might be composed by means of a programmed system, as is frequently the condition for OLTC, or a physical tap changer that is more typical for NLTC. Furthermore, our tap changers are frequently set on the elevated current (low voltage) transformer twisting for simple access as well as to limit the voltage load amid working.

Key Features:

1) Amalgamates working of tap selector and diverter switch.
2) Reactor outlined for constant loading.
3) Deploys bridging position like a service position.
4) Carries load from single tap to the next.

Flange Mounted Onload Tapchangers (OLTC)

  • Connector Type:Terminal connectors
  • Frequency (MHz):50 Hz/60 Hz
  • Input Voltage:11 kV to 33 kV typical range
  • Insulation Material:High-grade insulation material
  • Operating Temperature:-25C to +55C
  • Output Type:Load regulation
  • Power Factor:High

Tapchanger Control and Health Monitoring System

  • Connector Type:Screw Terminal
  • Frequency (MHz):50 Hz
  • Humidity %:Up to 95% RH (Non-Condensing)
  • Input Voltage:110/230 V AC
  • Operating Temperature:-10C to +60C
  • Output Type:Digital/Relay Output
  • Size:Standard

High Power Intank Onload Tapchangers (Oltc) for Transformers

  • Connection Type:Internal connection
  • IP Rating:IP55
  • Material:Metal and insulated components
  • Mounting Type:Intank mounting
  • Product Type:Intank Onload Tapchanger (OLTC)
  • Protection Level:Other, High
  • Warranty:1-2 years

Ester Oil Filled Onload Non Vaccum Tapchangers

  • Application:Transformer tap changers
  • IP Rating:IP64
  • Material:High-grade steel and insulation components
  • Mounting Type:Integrated within transformer casing
  • Product Type:Ester Oil Filled Onload Non-Vacuum Tapchangers
  • Protection Level:High, Other
  • Warranty:1 year

Dry Type Vacuum Onload Tapchangers

  • Connection Type:Panel mounted
  • IP Rating:IP54
  • Material:Metal frame and insulated materials
  • Mounting Type:Floor-mounted
  • Product Type:Dry Type Vacuum Onload Tapchanger
  • Protection Level:Other, High-grade protective enclosure
  • Warranty:1 year

Dry Type Air Switching Onload Tapchangers

  • Input Voltage:Varies with configuration
  • Insulation Material:High-grade insulation materials
  • Operating Temperature:-20C to 50C
  • Overheating Protection:Built-in mechanism, Other
  • Phase:Three-phase
  • Power Factor:High
  • Size:Compact/customizable

Off Circuit Tapchangers

  • Dimension (L*W*H):Customizable
  • Energy Consumption:Low
  • Feature:Provides reliable voltage adjustment
  • No Of Poles:Single or Multiple
  • Rated Voltage:Based on customer specifications
  • Shape:Rectangular Frame
  • Weight:Dependent on design specifications

Remote Tapchanger Control Cubicle for Onload Tapchangers

  • Application:Onload Tapchangers
  • IP Rating:IP54
  • Material:Metal Enclosure
  • Mounting Type:Wall Mount
  • Product Type:Remote Tapchanger Control Cubicle
  • Protection Level:Other, High
  • Warranty:1 Year

Bushing Monitoring

Bushing Monitoring is designed and installed for the detection of deterioration in bushings, finding abnormalities in the insulation and issuing actionable alerts. This monitoring is embedded with Expert System to provide you with notifications and alarms based on comparisons between off-line and calculated on-line data. It can be operated as a standalone device as well as can be fitted with other monitoring devices. This intelligent device is used to calculate values for power factor & capacitance as well as bushing current waveforms in real time.

Pressed Steel Radiators

Pressed Steel Radiators are widely used in oil immersed transformers Parts to ascertain leakages. These radiators are highly effective in distribution transformers Parts. They are reliable and offer safe operations for a longer period of time. These radiators are manufactured using high-quality stainless steel with the aid of latest technologies. They are tested on various parameters to ensure the quality as well as the safety of the product. The radiators are available in various specifications and dimensions as well as can be customized according to the clients requirements.

Substation Automation Systems

Substation Automation Systems are manufactured using the premium quality components with the aid of latest technology in adherence to the defined market standards of quality. These systems are used for monitoring various industrial processes. The excellent functionality and optimum performance of these systems are helpful in saving time and human effort. They are easy to operate and control without any efforts. These automation systems are tested on various parameters to ensure the safety as well as the quality of the product.

Intank On Load Tap Changers

Intank on Load Tap Changers are fitted into the tanks to facilitate their smooth working. These tap changers are manufactured with the utilization of fine grade components under the strict direction of experienced professionals. They are also helpful for regulating the output voltage of larger power, furnace, rectifier and generator transformers Parts. These changers are indispensable in regulating power transformers Parts. They can be bolted directly to a port flange on the transformer Parts. The tap changers have high operational fluency, simple functionality, and longer service life.

Dry Type Tapchangers

Dry Type Tapchangers are highly demanded due to their high performance and elevated durability. These tapchangers have an anti-corrosive body and are manufactured with the aid of latest techniques. They are used in various types of transformers Parts that allow for variable turn ratios to be selected in discrete steps. These tapchangers are available in various specifications and dimensions as well as can be customized as per requirement of the customer. They are globally appreciated for their hassle free operation and high functionality.

Intank Tap Changer

On Intank Tap Changer is indispensable in regulating power transformers. It is used in electrical energy networks to enable voltage regulation and phase shifting by varying the transformer ratio under load without interruption. Owing to excellent energy efficiency and excellent performance, it is extensively preferred by clients across the industry. Apart from this, it can be also availed from us in different specifications as per the requirement.

Flange Mounted On Load Tap Changer

Flange Mounted On Load Tap Changer is widely used to control power distribution to individual loads and also provides security for load cables. It is installed on various devices for regulating the output voltage of lower capacity power, distribution, furnace, and rectifier transformers Parts. This top charger is manufactured by a team of adroit professionals using high-quality components with the aid of latest technology. It is easy to use, highly durable and longer service life.
X


Back to top